首页> 外文期刊>Padjadjaran Journal of Dentistry >Comparison distortion in the mandible skull using panoramic digital radiograpy and Cone Beam Computed Tomography
【24h】

Comparison distortion in the mandible skull using panoramic digital radiograpy and Cone Beam Computed Tomography

机译:使用全景数字射线照相和锥形束计算机断层扫描技术比较下颌骨的畸变

获取原文
           

摘要

Panoramic radiography is widely used as a tool supporting the diagnosis in dental practice. Currently the technology has evolved with the presence of radiographic imaging such as Cone Beam Computed Tomography (CBCT) that displays a three-dimensional picture. The purpose of this study was to determine large distortions that occur several regio in the mandible using digital panoramic radiographs and CBCT. Method experimental The research on one of the skull laboratories fitted staples vertically and horizontally in alveolar regions 31, 33, 35, 37, 41, 43, 45, 47, and then measured the length of the staples using the term digital. Furthermore, digital panoramic radiography performed with position 0 0 , +5 0 , +10 0 , -5 0 , -10 0 and CBCT radiography with 0 0 positions. Measurement description of radiopaque vertical and horizontal lines on digital panoramic radiographs and CBCT are computerized using the EZ software measurement menu. Calculating percentage distortion radiopaque overview of vertical and horizontal lines on digital panoramic radiographs and CBCT of the mandible by doing a comparison of the actual size of the skull. The results obtained on the percentage of minimal distortion of digital panoramic radiographs vertically was in the 31 region positioned +5 0 at 0,23%, in the 33 region positioned 0 0 at 5,99%, in the 35 region positioned -10 0 at -6,33%, in the 37 region positioned +10 0 at -1,46%, in the 41 region positioned -5 0 at 0,46%, in the 43 region positioned 0 0 at 0,52%, in the 45 region positioned +10 0 at -0,45%, in the 47 region positioned +10 0 at -4,76%. The percentage of minimal distortion of digital panoramic radiographs horizontally all of region was positioned 0 0 . The percentage of minimal distortion of? CBCT all of region was positioned 0 0 and different on each mandible alveolar region. The conclusion of this study is average distortion that occurs in the mandible using CBCT is more less than digital panoramic radiographs. That is mean CBCT more accurate than digital panoramic radiographs.
机译:全景射线照相术被广泛用作支持牙科实践诊断的工具。当前,随着影像学成像技术的发展,例如显示三维图像的锥束计算机断层扫描(CBCT)。这项研究的目的是确定使用数字全景X射线照片和CBCT在下颌骨中发生几个区域的大畸变。方法实验在一个头骨实验室中进行的研究将钉书钉垂直和水平地安装在牙槽区域31、33、35、37、41、43、45、47中,然后使用数字一词测量钉书钉的长度。此外,以位置0 0,+5 0,+10 0,-5 0,-10 0进行数字全景射线照相,并以0 0位置进行CBCT射线照相。使用EZ软件测量菜单可以将数字全景X射线照片和CBCT上不透射线的垂直线和水平线的测量描述计算机化。通过对头骨的实际大小进行比较,计算数字全景X线照片上的垂直和水平线的畸变不透射线总览图和下颌骨的CBCT。在垂直方向上数字全景X射线照片的最小失真百分比上获得的结果是:位于+5 0处为0.23%的31个区域,位于0 0处为5,99%处的33个区域,位于-10 0中的35个区域在-6,33%处,在+10 0处在-1,46%处的37个区域中,在-5 0处在0.46%处的41个区域中,在0 0处在0.52%处的43个区域中, 45个区域位于+10 0处为-0.45%,而47个区域位于+10 0处为-4.76%。数字全景X射线照片水平区域的最小失真百分比位于0 0。最小失真百分比? CBCT所有区域的位置都为0 0,并且在每个下颌骨牙槽区域上都不同。这项研究的结论是,使用CBCT在下颌骨中发生的平均畸变比数字全景X线照片要少。这意味着CBCT比数字全景X射线照片更准确。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号