This study compares the methods of Dunn and Shukla in determining the appropriate insertion length of umbilical catheters. In July 2007, we changed our policy for umbilical catheter insertions from the method of Dunn to the method of Shukla. We report our percentage of inaccurate placement of umbilical-vein catheters (UVCs) and umbilical-artery catheters (UACs) before and after the change of policy. In the Dunn-group, 41% (28/69) of UVCs were placed directly in the correct position against 24% (20/84) in the Shukla-group. The position of the catheter-tip of UVCs in the Dunn-group and the Shukla-group was too high in 57% (39/69) and 75% (63/84) of neonates, respectively. UACs in the Dunn-group were placed directly in the correct position in 63% (24/38) compared to the 87% (39/45) of cases in Shukla-group. The position of the catheter-tip of UACs in the Dunn-group and the Shukla-group was too high in 34% (13/38) and 13% (6/45) of neonates, respectively. In conclusion, the Dunn-method is more accurate than the Shukla-method in predicting the insertion length for UVCs, whereas the Shukla-method is more accurate for UACs.
机译:这项研究比较了Dunn和Shukla在确定合适的脐带导管插入长度方面的方法。 2007年7月,我们将脐带导管插入的政策从Dunn方法更改为Shukla方法。我们报告了政策变更前后,脐静脉导管(UVC)和脐动脉导管(UAC)放置不正确的百分比。在邓恩组中,将41%(28/69)的UVC直接放置在正确的位置,而舒克拉组中则为24%(20/84)。在Dunn组和Shukla组中,UVC导管尖端的位置分别过高,分别为57%(39/69)和75%(63/84)的新生儿。 Dunn组中的UAC直接放置在正确位置的比例为63%(24/38),而Shukla组中为87%(39/45)。在Dunn组和Shukla组中,UAC的导管尖端位置过高,分别为34%(13/38)和13%(6/45)的新生儿。总之,在预测UVC的插入长度方面,Dunn方法比Shukla方法更准确,而对于UAC,Shunkla方法更准确。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号