A 43-year-old drug addicted female was referred for a L5-S1 posterolateral in situ fixation with autologous graft because of an L5/S1 severe discopathy with listhesis. After six months, low back pain recurred. A Tc-99m HDP SPECT-CT diagnosed a pseudarthrosis with intense uptake of the L5-S1 endplates and a fracture of the right S1 screw just outside the metal-bone interface without any uptake or bone resorption around the screw. The absence of uptake around a broken screw is a pitfall that the physician should be aware of.
机译:一名43岁的吸毒成年女性因L5 / S1严重的椎间盘突出症而被自体移植L5-S1后外侧原位固定。六个月后,腰痛再次出现。 Tc-99m HDP SPECT-CT诊断为假关节,其L5-S1终板被大量摄取,而右S1螺钉的骨折恰好位于金属-骨界面之外,而螺钉周围没有任何吸收或骨吸收。螺钉周围没有摄取物是医师应注意的陷阱。