摘要

The local concentration of dissolved oxygen over a metal-coated steel sample of cut-edge geometry was recorded by using either an amperometric probe or an optode (fibre-optic oxygen micro-sensor). Hydroxide ions, being the product of the current determining reaction on the amperometric micro-probe, were found to change the chemical composition of corrosion products. Application of an O-2 selective micro-optode for local measurements allows avoiding the indicated problem and is reported here for the first time when applied to localized corrosion measurements. The concentration of dissolved oxygen was mapped 100 mu m above the cut-edge steel coated with Al-Zn--Mg alloy. This was performed quasi-simultaneously with rastering local current density and pH over the same sample area. (C) 2015 Elsevier Ltd. All rights reserved.
机译:通过使用安培探针或光电二极管(光纤氧气微传感器)记录尖端几何形状的金属涂层钢样品上溶解氧的局部浓度。发现氢离子是电流测定微探针上电流确定反应的产物,它会改变腐蚀产物的化学组成。将O-2选择性微光电二极管用于局部测量可避免出现指示的问题,并且在首次应用于局部腐蚀测量时在此首次报道。测得的溶解氧浓度是在涂有Al-Zn-Mg合金的尖端钢上方100μm处绘制的。在相同的样品区域内,通过光栅化局部电流密度和pH值近似同时进行该操作。 (C)2015 Elsevier Ltd.保留所有权利。