首页> 美国卫生研究院文献>Journal of Clinical Laboratory Analysis >Role of anti‐transglutaminase (anti‐tTG) anti‐gliadin and anti‐endomysium serum antibodies in diagnosing celiac disease: A comparison of four different commercial kits for anti‐tTG determination
【2h】

Role of anti‐transglutaminase (anti‐tTG) anti‐gliadin and anti‐endomysium serum antibodies in diagnosing celiac disease: A comparison of four different commercial kits for anti‐tTG determination

机译:抗转谷氨酰胺酶(anti-tTG)抗麦醇溶蛋白和抗内胚层血清抗体在乳糜泻诊断中的作用:四种用于tTG测定的商业试剂盒的比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The aims of this study were: (1) to compare the diagnostic efficacy for celiac disease (CD) diagnosis of serum determination of anti‐gliadin (AG) (IgA and IgG) and anti‐endomysium (AE) with that of anti‐transglutaminase (AtTG); and (2) to compare the accuracy of four different assays to measure AtTG. We studied 72 children: the histological diagnosis of CD was made in 38 cases and excluded in the remaining 34 children. In fasting sera we measured AE, AG‐IgA and IgG, and AtTG, the latter with four different commercial kits (Eurospital, Medipan, Inova, Arnika). Moreover AtTG was measured in a group of 58 CD children after a gluten‐free diet. AE was positive in all but 1 case of CD patients (sensitivity = 97%); false positive results were found in 1/34 controls (specificity = 97%). When a specificity of 95% was fixed, the sensitivities were 97% for AE, 83% for AG‐IgA, and 63% for AG‐IgG; the sensitivities of anti‐tTG were 90, 84, 84, and 75% when measured with Eurospital, Medipan, Inova, and Arnika kits respectively. The new AtTG seems to be accurate enough to be proposed as a noninvasive diagnostic tool for CD diagnosis; the 4 kits analyzed showed similar diagnostic efficacy. J. Clin. Lab. Anal. 15:112–115, 2001. © 2001 Wiley‐Liss, Inc.
机译:这项研究的目的是:(1)比较乳糜泻(CD)和抗转谷氨酰胺酶对血清抗麦醇溶蛋白(AG)(IgA和IgG)和抗内膜肌层(AE)的测定对乳糜泻(CD)诊断的诊断功效(AtTG); (2)比较四种不同的测量AtTG的准确性。我们研究了72名儿童:CD的组织学诊断为38例,其余34例被排除。在空腹血清中,我们测量了AE,AG-IgA和IgG,以及AtTG,后者使用了四种不同的商业试剂盒(Eurospital,Medipan,Inova,Arnika)。此外,在58位无麸质饮食的CD儿童中测量了AtTG。除1例CD患者外,AE均为阳性(敏感性= 97%);在1/34对照中发现假阳性结果(特异性= 97%)。当固定特异性为95%时,AE的敏感性为97%,AG-IgA的敏感性为83%,AG-IgG的敏感性为63%。当使用Eurospital,Medipan,Inova和Arnika试剂盒测量时,抗tTG的敏感性分别为90、84、84和75%。新的AtTG似乎足够准确,可以作为CD诊断的非侵入性诊断工具提出。分析的4种试剂盒显示出相似的诊断功效。 J.临床实验室肛门15:112–115,2001。©2001 Wiley-Liss,Inc.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号