首页> 美国卫生研究院文献>other >Lateral Tip Control Effects in CD-AFM Metrology: The Large Tip Limit
【2h】

Lateral Tip Control Effects in CD-AFM Metrology: The Large Tip Limit

机译:CD-AFM量测中的横向笔尖控制效果:最大笔尖限制

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Sidewall sensing in critical dimension atomic force microscopes (CD-AFMs) usually involves continuous lateral dithering of the tip or the use of a control algorithm and fast response piezo actuator to position the tip in a manner that resembles touch-triggering of coordinate measuring machine (CMM) probes. All methods of tip position control, however, induce an effective tip width that may deviate from the actual geometrical tip width. Understanding the influence and dependence of the effective tip width on the dither settings and lateral stiffness of the tip can improve the measurement accuracy and uncertainty estimation for CD-AFM measurements.Since CD-AFM typically uses tips that range from 15 nm to 850 nm in geometrical width, the behavior of effective tip width throughout this range should be understood. The National Institute of Standards and Technology (NIST) has been investigating the dependence of effective tip width on the dither settings and lateral stiffness of the tip, as well as the possibility of material effects due to sample composition. For tip widths of 130 nm and lower, which also have lower lateral stiffness, the response of the effective tip width to lateral dither is greater than for larger tips. However, we have concluded that these effects will not generally result in a residual bias, provided that the tip calibration and sample measurement are performed under the same conditions.To validate that our prior conclusions about the dependence of effective tip width on lateral stiffness are valid for large CD-tips, we recently performed experiments using a very large non-CD tip with an etched plateau of approximately 2 μm width. The effective lateral stiffness of these tips is at least 20 times greater than typical CD-AFM tips, and these results supported our prior conclusions about the expected behavior for larger tips. The bottom-line importance of these latest observations is that we can now reasonably conclude that a dither slope of 3 nm/V is the baseline response due to the induced motion of the cantilever base.
机译:临界尺寸原子力显微镜(CD-AFM)中的侧壁感测通常涉及尖端的连续横向抖动或使用控制算法和快速响应压电致动器以类似于坐标测量机的触摸触发的方式来定位尖端( CMM)探针。然而,所有尖端位置控制方法都会产生有效的尖端宽度,该有效尖端宽度可能会偏离实际的几何尖端宽度。了解有效尖端宽度对抖动设置和尖端横向刚度的影响和依赖性可以提高CD-AFM测量的测量精度和不确定性估计。因为CD-AFM通常使用15 nm至850 nm范围内的尖端几何宽度,应了解整个范围内有效尖端宽度的行为。美国国家标准技术研究院(NIST)一直在研究有效笔尖宽度对抖动设置和笔尖横向刚度的依赖性,以及由于样品成分而产生材料影响的可能性。对于130 nm及以下的尖端宽度(也具有较低的侧向刚度),有效尖端宽度对横向抖动的响应要大于较大尖端的响应。但是,我们得出的结论是,只要在相同条件下进行尖端校准和样品测量,这些影响通常不会导致残留偏差。为验证我们先前关于有效尖端宽度对侧向刚度的依赖性的结论是正确的对于大型CD笔尖,我们最近使用非常大的非CD笔尖进行了实验,该笔尖的蚀刻平台宽度约为2μm。这些尖端的有效侧向刚度至少比典型CD-AFM尖端大20倍,这些结果支持了我们先前关于较大尖端的预期性能的结论。这些最新发现的底线重要性在于,我们现在可以合理地得出以下结论:由于悬臂基座的感应运动,抖动斜率为3 nm / V是基线响应。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号