Contrast sensitivity of digital imaging display systems: Contrast threshold dependency on object type and implications for monitor quality assurance and quality control in PACS

机译:数字成像显示系统的对比度灵敏度:阈值对对象类型的依赖性以及对PACS中监视器质量保证和质量控制的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The American Association of Physicists in Medicine Task Group 18 has published standards and quality control (QC) guidelines to ensure consistency and optimal quality for digital image display systems (DIDSs). In many of these recommended QC tests, static test patterns that contain low-contrast objects are often used to assess and validate the quality of a DIDS. These low-contrast objects often have the shape of circular disks or squares with sharp edges, neither of which resemble most of the diagnostic findings in medical images. On the other hand, circular objects with fuzzy boundaries bear a closer resemblance to lung nodules in chest radiography and masses in mammography; thus, they may be more clinically relevant in assessing display system quality. In this article human observers’ contrast sensitivities of circular objects with sharp edges and those with fuzzy ones were investigated. The contrast thresholds of human viewers using a consumer-grade color LCD monitor and a medical-grade monochrome LCD monitor were measured for objects of various sizes displayed against uniform backgrounds with various luminance levels. Contrast-detail curves for circular objects with sharp edges and those with fuzzy boundaries were measured and compared. It was found that contrast thresholds for objects with fuzzy boundaries were higher (i.e., the objects were more difficult to detect) than those with sharp edges. Objects with fuzzy boundaries were potentially more sensitive in distinguishing quality differences among image display devices and thus may be a better QC measurement in detecting subtle deterioration in image display devices.
机译:美国医学物理学会协会任务组18已发布标准和质量控制(QC)指南,以确保数字图像显示系统(DIDS)的一致性和最佳质量。在许多建议的QC测试中,经常使用包含低对比度对象的静态测试模式来评估和验证DIDS的质量。这些低对比度的对象通常具有带有尖锐边缘的圆盘或正方形的形状,这两种形状都不像医学图像中的大多数诊断结果。另一方面,带有模糊边界的圆形物体与胸部X线摄影中的肺结节和乳房X线摄影中的肿块更相似。因此,它们在评估显​​示系统质量方面可能在临床上更相关。在本文中,研究人员观察了带有尖锐边缘的圆形物体和带有模糊边缘的圆形物体的对比敏感度。使用消费级彩色LCD监视器和医疗级单色LCD监视器,针对在具有各种亮度级别的均匀背景下显示的各种尺寸的对象,测量了人类观众的对比度阈值。测量并比较了具有尖锐边缘的圆形对象和具有模糊边界的圆形对象的对比度细节曲线。发现具有模糊边界的物体的对比度阈值比具有锋利边缘的物体的对比度阈值更高(即,物体更难以检测)。具有模糊边界的对象在区分图像显示设备之间的质量差异时可能更敏感,因此在检测图像显示设备中的细微劣化方面可能是更好的QC测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号