摘要

后处理设施给水系统是后处理设施重要的公用系统,对后处理设施的稳定、安全运行至关重要.给水系统的可靠性需要深入分析,应用GO法进行了研究.获得了给水系统的平均故障概率、最小割集、重要度等可靠性指标.结果表明,给水系统的可靠性比较高,符合单一故障准则,二阶最小割集对系统故障的贡献最大,应该采取措施予以消除.进一步深入对比分析GO法与故障树法,结果显示,对于给水系统的可靠性分析,GO法有建模容易且图形简洁的优点.%The water supply system in a typical reprocessing facility is an important utility, which greatly influences steady and safety operation of the reprocessing facility.Since the reliability of the water supply system was required for deep analysis, GO methodology was applied to research for it.Reliability index such as average fault probability and minimal cut sets and their importance of the system were obtained in the research results.The results showed that the reliability of the system was very high and the system obeyed single fault principle.Since second order minimal cut sets contributed to the system fault mostly, some measures should be taken to eliminate them.Deeply parallel analysis between GO methodology and fault tree methodology was performed furthermore.The results showed that the modeling was much easier and the chart was much more succinct for GO methodology parallel with fault tree methodology to analyze the reliability of the water supply system.

著录项

  • 来源
    《环境科学与管理》 |2017年第8期|116-120|共5页
  • 作者单位

    中国辐射防护研究院核应急与核安全研究所,山西 太原 030006;

    中国辐射防护研究院核应急与核安全研究所,山西 太原 030006;

    中国辐射防护研究院核应急与核安全研究所,山西 太原 030006;

    中国辐射防护研究院核应急与核安全研究所,山西 太原 030006;

    中国辐射防护研究院核应急与核安全研究所,山西 太原 030006;

    中国辐射防护研究院核应急与核安全研究所,山西 太原 030006;

    中国辐射防护研究院核应急与核安全研究所,山西 太原 030006;

    中国辐射防护研究院核应急与核安全研究所,山西 太原 030006;

    中国辐射防护研究院核应急与核安全研究所,山西 太原 030006;

  • 原文格式 PDF
  • 正文语种 chi
  • 中图分类 技术方法;
  • 关键词

    后处理; 可靠性; GO法; 故障树;

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号