首页> 外文学位 >Methodology for the selection and evaluation of computer input devices for people with functional limitations.
【24h】

Methodology for the selection and evaluation of computer input devices for people with functional limitations.

机译:为有功能限制的人选择和评估计算机输入设备的方法。

获取原文
获取原文并翻译 | 示例

摘要

Many computer users with motor impairments frequently use standard input devices even though these devices are not best suited for them. A methodology for specifying alternative assistive input devices as a function of type and degree of functional limitation is important for improving access to computer technology. The current research developed a matrix for matching assistive technology input devices to the assessed level of functional limitation. Since there are few reliable input device assessment instruments for people with impairments, this research also developed and validated a methodology for assessing the level of impairment for people with upper-limb motor impairments.; Computer pointing task performance for 23 unimpaired participants (mean = 28.2 years, SD = 5.7 years) and 11 participants with upper extremity impairments (mean = 25.8 years, SD = 10.0 years) was evaluated using three input devices (joystick, trackball, and mouse) and a Fitts' Law test. Impairments represented in this study included cerebral palsy, spina bifida, head injury, muscular dystrophy, spinal cord injuries, and multiple disabilities. The Minnesota Manual Dexterity Test (MMDT) was used to assess manual dexterity. Each Fitts' Law target was square in shape with a width of 5, 15, or 25 mm. Movement amplitude from the start point to the center of the target was 40, 80, or 160 mm. Movement directions for the unimpaired group were 0 (East), 90 (North), and 225 (Southwest) degrees, but were limited to 0 and 90 degrees for participants with impairments. The control-display (CD) gains used in this study were 0.5 and 1.0. There was one practice session and two main sessions. In each run, each combination of target size, movement amplitude and movement direction appeared four times in random order. A separate run was conducted for each device and CD gain combination. Each unimpaired participant pointed to 108 targets per run and participants with impairments pointed to 72 targets per run.; Fitts' Law was a valid model of performance for assessing the levels of impairment for both groups. Movement time (MT) and Fitts' Law index of performance (IP) correlated strongly with the MMDT scores and served as valid metrics for assessing the use of computer input devices by people with upper-limb motor impairments. This research developed and validated a sound approach to input device selection and functional limitation assessment to improve the match between computer pointing task requirements and the capabilities of challenged users.
机译:许多有运动障碍的计算机用户经常使用标准输入设备,即使这些设备并非最适合他们。根据功能限制的类型和程度来指定其他辅助输入设备的方法对于改进对计算机技术的访问非常重要。当前的研究开发了一个矩阵,用于将辅助技术输入设备与评估的功能限制水平进行匹配。由于几乎没有针对残障人士的可靠输入设备评估工具,因此本研究还开发并验证了一种评估上肢运动残障人士的残障程度的方法。使用三个输入设备(游戏杆,轨迹球和鼠标)评估了23名无障碍参与者(平均= 28.2年,SD = 5.7年)和11名上肢肢体受损(平均= 25.8年,SD = 10.0年)的计算机指向任务性能)和费茨定律测试。在这项研究中代表的障碍包括脑瘫,脊柱裂,头部受伤,肌肉营养不良,脊髓损伤和多发性残疾。明尼苏达州人手敏捷测试(MMDT)用于评估手敏捷性。每个《费茨定律》目标都是正方形,宽度为5、15或25毫米。从起点到目标中心的移动幅度为40、80或160 mm。无障碍组的运动方向为0(东),90(北)和225(西南)度,但对于有障碍的参与者,运动方向限制为0和90度。在这项研究中使用的控制显示(CD)增益分别为0.5和1.0。举行了一次实践会议和两次主要会议。在每次运行中,目标大小,运动幅度和运动方向的每种组合均以随机顺序出现四次。对每个设备和CD增益组合进行了单独的运行。每位无障碍的参与者指出每次跑步108个目标,有障碍的参与者指出每次跑步72个目标。菲茨定律是评估两组损伤程度的有效绩效模型。运动时间(MT)和性能的菲茨法则性能指数(IP)与MMDT得分密切相关,并用作评估上肢运动障碍患者使用计算机输入设备的有效指标。这项研究开发并验证了一种有效的输入设备选择和功能限制评估方法,以改善计算机定位任务要求与受挑战用户的能力之间的匹配。

著录项

  • 作者

    Hwang, Byeong-Cheol.;

  • 作者单位

    The University of Oklahoma.;

  • 授予单位 The University of Oklahoma.;
  • 学科 Engineering Industrial.; Health Sciences Occupational Health and Safety.
  • 学位 Ph.D.
  • 年度 2001
  • 页码 240 p.
  • 总页数 240
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 一般工业技术;职业性疾病预防;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号