Fan Testing: Determining the Most Effective Size and Location of Odor Control Facilities

机译:风扇测试:确定气味控制设施的最有效尺寸和位置

获取原文

摘要

The use of vapor phase odor control facilities within the collection system has becomeincreasingly frequent in recent years. However, properly sizing and locating vapor phase odorcontrol facilities within the collection system is more complicated than liquid phase (chemical)treatment alternatives. The ventilation dynamics of the collection system, and the desired zone ofinfluence of the odor control facility, will dictate the necessary airflow capacity for an effectivevapor phase odor control system. A fan test is conducted to determine the most effective airextraction point(s) and confirm the volume of air necessary to depressurize the sewers. Byextracting known volumes of air over the course of a typical diurnal flow period, it is possible tosimulate the depressurization effects of a proposed vapor phase odor control facility at the testlocation.
机译:近年来,在收集系统中使用气相臭味控制设施变得越来越频繁。但是,在收集系统中正确设置蒸气相气味控制设施的大小和位置要比液相(化学)处理方法复杂得多。收集系统的通风动力学以及气味控制设施的理想影响区域将决定有效的气相异味控制系统所需的空气流量。进行风扇测试以确定最有效的空气抽出点,并确定使下水道减压所需的空气量。通过在典型的昼间流量期间提取已知体积的空气,可以模拟拟议中的气相气味控制设备在测试位置的降压效果。