The start-up of the Clark County Water Reclamation District (District) Moapa Valley WaterResource Center (MVWRC) presented several operational challenges. The influent flow andorganic load was significantly less than the design minimum as the project schedule occurredduring an unexpected economic turndown - that continues on today. In order to accelerate startup,the basins were seeded with thickened waste activated sludge from the District’s MainCentral Plant in Las Vegas. Instead of growing and stabilizing, the biomass essentiallydisappeared in a matter of weeks after seeding, resulting in a sharp decrease of the mixed liquorsuspended solids concentration. Start-up troubleshooting indicated that a combination of solidssettling, midge fly larvae invasion, uncontrolled solids wasting, and biofilm formation on tankwalls caused the initial biomass instability. Inconsistent plant performance was also observedduring start-up. Process modeling and field observations indicated that reduced organic load,excessive aeration, and biomass instability were the major causes of the inconsistent processperformance. Process modifications were identified and implemented to address the start-upchallenges experienced by District staff. Supplemental carbon was implemented on anemergency basis. The process configuration and aeration control were modified to minimizeexcessive aeration. The return activated sludge and mixed liquor internal recycle flows wereadjusted to minimize solids settling in the structures. As a result of the start-up optimizationeffort, the MVWRC consistently exceeds both the design treatment goals and the mandatedpermit requirements.
机译:克拉克县水垦区(区)Moapa Valley水资源中心(MVWRC)的启动带来了一些运营挑战。由于项目进度在意​​料之外的经济不景气下发生,因此进水流量和有机负荷显着低于设计最小值,这种情况一直持续到今天。为了加快启动速度,在盆地上撒了来自拉斯维加斯地区MainCentral工厂的增稠的废活性污泥。而不是生长和稳定,生物量基本上在播种后的几周内消失,导致混合液悬浮固体浓度的急剧下降。启动故障排除表明,固体沉降,mid蝇幼虫入侵,固体废物失控和罐壁上生物膜的形成共同导致了初始生物量不稳定。在启动过程中还观察到不一致的工厂性能。过程建模和现场观察表明,减少的有机负荷,过度的充气和生物量的不稳定性是导致过程性能不一致的主要原因。确定并实施了流程修改,以解决地区工作人员遇到的启动挑战。补充碳是在紧急情况下实施的。修改了工艺配置和曝气控制,以最大程度地减少过度曝气。调节了回流的活性污泥和混合液的内部循环流量,以最大程度地减少固体在结构中的沉降。作为启动优化工作的结果,MVWRC始终超过设计处理目标和强制许可要求。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号