A laboratory investigation of discharge pattern evolution as a function of electrical aging has been carried out for internal partial discharge (PD) and external corona activity. The setup was composed of three stator bars. The groundwall insulation of only one bar was exposed to high voltage. A second bar was not exposed directly to high voltage but was crossing over the first bar in the end arm region. From the evolution of the phase resolved discharge pattern, monitored over 3000 hours, internal discharges were easily distinguishable from end arm corona. The phase angle at which both types of activity occurred revealed some difference indicating mat different discharge mechanisms were involved. A third bar used as an antenna was not subjected to any discharge activity and was monitored to determine the amount of electromagnetic coupling occurring at different frequencies. Some of the information found can be extrapolated to rotating machine monitoring to determine the presence of end arm corona.
机译:对于内部局部放电(PD)和外部电晕活性,已经进行了放电模式演变与电老化的关系的实验室研究。该装置由三个定子棒组成。只有一根钢筋的接地绝缘层暴露于高压下。第二条没有直接暴露在高压下,而是在末端臂区域中越过了第一条。从3000小时内监测到的相分辨放电模式的演变来看,内部放电与端臂电晕很容易区分开。两种类型的活动发生的相角显示出一些差异,表明涉及不同的放电机理。用作天线的第三条没有任何放电活动,并受到监测以确定在不同频率下发生的电磁耦合量。可以将发现的某些信息外推至旋转机械监控器,以确定端臂电晕的存在。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号