Microcystis aeruginosa is common in freshwater lakes, and developed easy. Instead of chlorophyll standard substance, fresh chlorophyll extraction from Microcystis aeruginosa applied to the determination of chlorophyll-a in water by fluorophotometry. Thus the relationship between concentration of chlorophyll-a and fluorescence intensity of Microcystis aeruginosa in water was established. The fluorescence intensity responded with the concentration of chlorophyll-a extract linearly in the range of 30-1800 ug/L with a correlative coefficient of 0.9947. Comparision was made between chlorophyll standard and the chlorophyll-a extraction of Microcystis aeruginosa, and no significant difference was found. In certain range of pH value and time, chlorophyll-a extraction from Microcystis aeruginosa is stable, and can be used to reflect the growth of algae in water quick. conveniently and accurately.
机译:微囊杆菌铜绿假单胞菌在淡水湖泊中很常见,并且易于发展。代替叶绿素标准物质,通过荧光体测定氟纤维铜绿假单胞菌的新鲜叶绿素提取,荧光体测定水中叶绿素-A在水中的测定。因此,建立了水中叶绿素-A浓度与水中铜绿素A和荧光强度之间的关系。荧光强度随着叶绿素-A提取物的浓度线性地在30-1800ug / L的范围内响应,其相关系数为0.9947。在叶绿素标准和叶绿素 - 炸药铜绿假单胞菌的提取之间进行比较,发现没有显着差异。在某些PH值和时间范围内,叶绿素-A从微囊杆菌铜绿素萃取是稳定的,并且可用于反映水中藻类的生长。方便,准确。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号