Level 2 full power and shutdown PSA has been performed for the post-reconstruction status of the plant. The paper describes the main steps of the analyses and the results. The overall conclusion of the study is that the reconstruction significantly improved the plant safety. The most important benefits are, firstly, the confinement failure probability is reduced and secondly, the source terms are reduced in case of severe accidents.
机译:2级全电源和关机PSA已经为工厂的重建状态执行。本文描述了分析的主要步骤和结果。该研究的整体结论是重建显着提高了植物安全性。首先,限制失败概率最重要的益处,其次,在严重事故的情况下,源术语减少。