Radial Artery Reactive Response and Shear Rate Measurements Using 20 MHz System

机译:使用20 MHz系统测量动脉反应性和剪切速率

获取原文

摘要

The article attempts to select an ultrasound system to assess of endothelium dysfunction-dependent flow mediated dilation (FMD) and shear rate (SR) in radial artery after several minutes of hyperaemia. Methods: We compare the effective axial resolution and Doppler sensitivity of the standard US working below 12 MHz and high frequency (close to 20 MHz) scanning systems measuring the vessel diameter and blood flow measurements in radial arteries. FMD and FMD and SR were measured in Control group of 14 healthy volunteers, and in 13 with stable coronary artery diseases (CAD). Results: In a laboratory experiment of imaging two closely spaced food plastic foils, over three times better axial resolution was demonstrated for the 20 MHz ultrasound system in which the resolution was close to 0.1 mm. Also the sensitivity of the external single 20 MHz pulse Doppler transducer proved to be over 20 dB better (in terms of signalto-noise ratio) than the pulse Doppler incorporated into the L14-5 linear array. FMD in Control group was in the range of 8=16% with mean±sd equal to 12.13 ± 2.34%; in CAD group FMD was in the range of 0.1=7 % with mean±sd equal to 3.01±2.18% which was significantly less. FMD/SR was equal to 3.08 ± 1.34 x 10-4 in Control group and 1.01 ± 0.76 x 10-4 in CAD group with ranges equal to 1.66 = 7.8 x 10-4 and 0.4 = 2.4 x 10-4, respectively. Conclusions: Increasing scanning and Doppler mode frequency to 20 MHz improved the precision of FMD and SR measurements. Statistically significant differences between the two groups were confirmed by statistical tests for FMD and FMD/SR with p-values <; 0.05. The results obtained suggest the usefulness of the proposed ultrasonic system for measurements of FMD and SR in the radial artery to differentiate normal subjects from those with CAD.
机译:这篇文章试图选择一种超声系统,以评估充血几分钟后radial动脉的内皮功能障碍依赖性血流介导的扩张(FMD)和剪切速率(SR)。方法:我们比较了在低于12 MHz的美国标准和高频(接近20 MHz)扫描系统测量血管直径和radial动脉血流测量的有效轴向分辨率和多普勒灵敏度。在14名健康志愿者的对照组和13名患有稳定冠状动脉疾病(CAD)的对照组中测量FMD,FMD和SR。结果:在对两个紧密间隔的食品塑料箔进行成像的实验室实验中,对于分辨率接近于0.1 mm的20 MHz超声系统,轴向分辨率被证明是其三倍以上。此外,事实证明,外部单个20 MHz脉冲多普勒换能器的灵敏度(就信噪比而言)比集成到L14-5线性阵列中的脉冲多普勒好20 dB以上。对照组FMD在8 = 16%的范围内,平均值±sd等于12.13±2.34%;在CAD组中,FMD在0.1 = 7%的范围内,平均值±标准偏差等于3.01±2.18%,显着降低。 FMD / SR等于3.08±1.34 x 10 -4 对照组为1.01±0.76 x 10 -4 在CAD组中,范围等于1.66 = 7.8 x 10 -4 和0.4 = 2.4 x 10 -4 , 分别。结论:将扫描和多普勒模式频率提高到20 MHz,可以提高FMD和SR测量的精度。通过FMD和FMD / SR的统计学检验,p值<;证实了两组之间的统计学显着性差异。 0.05。所获得的结果表明,所提出的超声系统对于测量F动脉中的FMD和SR的功能是有用的,可以将正常受试者与患有CAD的受试者区分开。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号