首页> 外文会议>Instrumentation and Measurement Technology Conference, 2002. IMTC/2002. Proceedings of the 19th IEEE >A comparison between different excitation/detection systems for luminescence lifetime based instrumentation
【24h】

A comparison between different excitation/detection systems for luminescence lifetime based instrumentation

机译:基于发光寿命的仪器的不同激发/检测系统之间的比较

获取原文

摘要

There are several interesting optical sensors based on the measurement of the decay time of luminescence quenching. Traditional systems to measure luminescence decay times use flash lamps as light sources and photomultipliers as transducers because of the characteristics of the sensors. Such equipment is large and expensive and cannot be considered practical for many purposes. In this paper, a comparison between different systems to measure phosphorescence lifetimes is presented. Four different combinations of light source and photo detector have been tested in order to determine their interest. The objective is to replace traditional devices by solid-state devices.
机译:基于发光猝灭的衰减时间的测量,有几种有趣的光学传感器。由于传感器的特性,用于测量发光衰减时间的传统系统使用闪光灯作为光源,使用光电倍增管作为传感器。这样的设备是大型且昂贵的,并且不能被认为在许多目的上是实用的。在本文中,比较了测量磷光寿命的不同系统之间的差异。为了确定它们的兴趣,已经测试了光源和光电检测器的四种不同组合。目的是用固态设备代替传统设备。