Quantitative measurement of Cerenkov light generated by spent fuel assemblies requires an understanding of the absorbance characteristics of the spent fuel pond water. The presence of particulate or organic material can severely attenuate the transmission of the ultraviolet component of the Cerenkov spectrum. This can make the quantitative measurement of the Cerenkov light using a digital Cerenkov viewing device difficult or in some cases impossible. A calibration light source that can be inserted into the fuel pond has been constructed. This source generates a known ultraviolet light flux. Measurements of this source can be used to calculate the absorbance of Cerenkov light by the fuel pond water and in turn compensate for the absorbance when measuring the intensity of a spent fuel assembly. This paper discusses the challenges of constructing such a device and the results from measurements in two spent fuel ponds.
机译:定量测量乏燃料组件产生的切伦科夫光需要了解乏燃料池水的吸收特性。颗粒或有机材料的存在会严重削弱切伦科夫光谱中紫外线成分的透射。这可能使使用数字切伦科夫观察装置对切伦科夫光进行定量测量变得困难或在某些情况下是不可能的。已经构造了可以插入到燃料池中的校准光源。该源产生已知的紫外光通量。该光源的测量值可用于计算燃料池水对切伦科夫光的吸收率,进而在测量乏燃料组件的强度时补偿吸收率。本文讨论了构建这种设备的挑战以及在两个乏燃料池中进行测量的结果。