The Central Store for Special Irradiated Fissionable Material (DCMFEI) is an old Argentine facility, designed to store LEU spent fuel assemblies discharged from the research reactors. Spent MTR fuels are normally stored inside concrete wells filled with water and closed with lead plugs on the top. The water is used as shielding and cooling media. Each well can accommodate up to two fuel assemblies. The facility is under the regulatory control of the Argentine Nuclear Regulatory Authority (ARN). On the other hand, the Brazilian-Argentine Agency for Accounting and Control of Nuclear Material (ABACC) and the International Atomic Energy Agency (IAEA) carry out safeguards inspections to this facility since the beginning of the implementation of the Quadripartite Agreement. The spent fuel assemblies are maintained under dual containment system by ABACC and IAEA, which requires the verification of fuel assemblies at research reactors and to maintain the continuity of knowledge during the transfers to the storage. The transfer campaign takes one week and it is carried out once per year. In order to reduce the inspection effort is proposed to remove all seals. In this case, the Safeguards Criteria for Storage Facilities request item counting and verification of the spent fuel for gross defect. Nevertheless, this task present some problems because the spent fuels are not always visible, then item counting is difficult. On the other hand, the introduction of detectors inside the wells is not always possible due to the small space available and the high doses involved when the wells remain opened. In order to overcame these difficulties ARN and ABACC have designed and tested a method to verify spent fuel assemblies using gamma spectrometry. Spectra were taken with a Cadmium Telluride detector (CZT). An ad hoc modified lead plug was used as detector collimator. The activity of each item was determined trough the main Cs-137 peak. Experience showed that it is possible to distinguish among one, two or no spent fuel assembly. Moreover, the activity measured on each well shows good correlation with the theoretical activity calculated considering burnup, decay time and shielding corrections.
机译:特殊辐照可裂变材料中央存储区(DCMFEI)是阿根​​廷的一家老设施,旨在存储从研究堆中排出的LEU乏燃料组件。用过的MTR燃料通常存储在充满水的混凝土井中,并在顶部用铅塞封闭。水用作屏蔽和冷却介质。每个井最多可容纳两个燃料组件。该设施受阿根廷核监管局(ARN)的监管控制。另一方面,自《四方协定》开始执行以来,巴西-阿根廷核材料核算和控制局(ABACC)和国际原子能机构(IAEA)对该设施进行了保障监督。 ABACC和IAEA将乏燃料组件维护在双重密闭系统下,这要求对研究堆的燃料组件进行验证,并在转移到存储过程中保持知识的连续性。转移活动需要一周的时间,并且每年进行一次。为了减少检查工作,建议拆除所有密封件。在这种情况下,《存储设施保障标准》要求对物品进行计数并核查是否有严重缺陷的乏燃料。然而,由于乏燃料并不总是可见的,因此该任务存在一些问题,因此难以计数。另一方面,由于可用空间很小并且当孔保持打开状态时所涉及的高剂量,不可能总是将检测器引入孔中。为了克服这些困难,ARN和ABACC设计并测试了一种使用伽马能谱仪验证乏燃料组件的方法。光谱用碲化镉检测器(CZT)拍摄。特设的改良铅塞用作检测仪准直仪。通过Cs-137主峰确定每个项目的活性。经验表明,可以区分一个,两个或没有乏燃料组件。此外,在每口井上测得的活度与考虑燃耗,衰减时间和屏蔽校正而计算出的理论活度显示出良好的相关性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号