首页> 外文会议>8th IEEE Symposium on Diagnostics for Electrical Machines, Power Electronics Drives >The influence of PWM voltage waveforms on induction motor insulation systems: Perspectives for the end user
【24h】

The influence of PWM voltage waveforms on induction motor insulation systems: Perspectives for the end user

机译:PWM电压波形对感应电动机绝缘系统的影响:最终用户的观点

获取原文

摘要

Inverter-fed motors may experience premature failures due to the abnormal (if compared with 50/60 Hz sinusoidal voltage) stress profiles that voltage impulses induce in the insulation system. This paper will briefly recall the reasons for these failures, focusing on the key role of partial discharges in wire-wound insulation systems. Furthermore, it will provide a short review of the actions taken by the International Electrotechnical Commission (IEC) to minimize the impact of such failures. Eventually, some solutions for testing online wire-wound motors, thus preventing premature failures to occur, will be presented.
机译:逆变器供电的电机可能会由于绝缘系统中的电压脉冲引起的异常(如果与50/60 Hz正弦电压相比)应力曲线而过早失效。本文将简要回顾一下造成这些故障的原因,重点是局部放电在绕线绝缘系统中的关键作用。此外,它将简短回顾国际电工委员会(IEC)采取的措施,以最大程度地减少此类故障的影响。最终,将介绍一些用于测试在线绕线电动机的解决方案,从而防止过早发生故障。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号