首页> 外文会议>2nd International Conference on Chemical, Biological and Environmental Engineering >Impact of RTD on NH3-N removal efficiency by three-phase internal fluidized bed
【24h】

Impact of RTD on NH3-N removal efficiency by three-phase internal fluidized bed

机译:三相内部流化床对RTD对NH 3 -N去除效率的影响

获取原文

摘要

This paper conducted the effects of residence time distribution (RTD) on NH3-N removal efficiency by three-phase internal fluidized bed. Pulse testing was applied under different flow patterns, using NaCl as the tracer. Then number of tank-in-series was determined to approach1 and the reactor could be considered as a Continuous Stirred-Tank Reactor(CSTR). Different HRT was compared and it concluded that as HRT =1.5h, volume utilization ratio reached the highest level, and the maximum removal efficiency of NH3-N(>90%) was obtained. These results validated the good reliability of the RTD testing, and provided the basic data and knowledge for determination the reactor size and scale-up ratio.
机译:本文研究了停留时间分布(RTD)对三相内部流化床脱除NH 3 -N效率的影响。使用NaCl作为示踪剂,在不同的流动模式下进行了脉冲测试。然后确定串联罐的数量接近1,并且该反应堆可以视为连续搅拌罐反应堆(CSTR)。比较了不同的HRT,得出结论:当HRT = 1.5h时,体积利用率达到最高水平,并获得最大的NH 3 -N(> 90%)去除率。这些结果验证了RTD测试的良好可靠性,并提供了确定反应器尺寸和放大比例的基本数据和知识。