Removal of micropollutants in aqueous streams by organophilic pervaporation

机译:通过亲有机渗透蒸发去除水流中的微量污染物

获取原文
获取原文并翻译 | 示例

摘要

In this work a laboratory pervaporation equipment using three different flat organophilic membranes: PERVAP1060 (Sulzer), POMS and PEBA (GKSS), for pure compounds (TCE, Ethylbenzene and MTBE) has been assembled to prove micropollutant separation. Previous membrane adsorption tests have been performed to pre-screen the most suitable membranes for each compound. The different parameters of the process, that is, membrane material, membrane thickness, water flowrate, solution temperature, initial feed concentration, operation time and vacuum pressure have been evaluated for the MTBE.