Enhanced biological phosphorous (Bio-P) removal process was adapted to membrane bioreactor (MBR). One bench-scale pilot plant (BSP, 200―250 L) and two medium-scale pilot plants (2//MSP, 1000―3000 L each) were operated under several configurations, including pre-denitrification and post-denitrification without addition of carbon source, and two solid retention times (SRT) of 15 and 26 d, in parallel to the full-scale Bio-P removal activated sludge plant of Berlin-Ruhleben (12―18 d SRT). The trials showed that efficient Bio-P removal can be achieved with MBR systems, in both pre- and post-denitrification configurations. Bio-P dynamics could be clearly demonstrated through batch-tests, on-line measurements, profile analyses, P-spiking trials, and mass balances. High P-removal performances were achieved even with high SRT of 26 d (around 9 mgP/L was removed with P/TS~2.6%). Under similar operation conditions of sludge age and mass organic load, the MBR system achieved slightly higher P-removal than the conventional technology. This was due to the rejection of particles and colloids through the microfiltration membrane. When spiking with phosphate, high Bio-P removal of up to 35―40 mg/L could be achieved without addition of external carbon source, and P/TS stabilized around 7.5%.
机译:增强的生物除磷(Bio-P)去除过程适用于膜生物反应器(MBR)。一个试验台规模的中试工厂(BSP,200-250 L)和两个中等规模的试验中的工厂(2 // MSP,每个1000-3000 L)在几种配置下运行,包括不进行脱氮前的反硝化和后脱氮碳源,两个固体保留时间(SRT)分别为15和26 d,与柏林-鲁勒本(Berlin-Ruhleben)的全规模Bio-P去除活性污泥厂(12-18 d SRT)平行。试验表明,在脱硝前后的配置中,MBR系统均可有效去除Bio-P。 Bio-P动力学可以通过批量测试,在线测量,轮廓分析,P加标试验和质量平衡来清楚地证明。即使在26 d的高SRT时也实现了较高的P去除性能(P / TS约为2.6%去除了约9 mgP / L)。在类似的污泥龄和大量有机负荷的运行条件下,MBR系统的除磷效果比常规技术略高。这是由于微粒和胶体通过微滤膜的排斥。当添加磷酸盐时,无需添加外部碳源就可以实现高达35-40 mg / L的高Bio-P去除,并且P / TS稳定在7.5%左右。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号