首页> 外文会议>International conference on structural engineering, mechanics and computation >Thermal and axial compression behaviour of full-scale concrete-filled steel-tube columns (RCFST) exposed to fire: Experimental study
【24h】

Thermal and axial compression behaviour of full-scale concrete-filled steel-tube columns (RCFST) exposed to fire: Experimental study

机译:火灾下全尺寸钢管混凝土柱(RCFST)的热和轴向压缩行为:实验研究

获取原文

摘要

This paper presents experimental results of fire and compression tests performed on full-scale fire-exposed Reinforced Concrete-Filled Steel Tubes (RCFST) and Reinforced Concrete (RC) short columns (outer diameter 457 mm and length 1600 mm). In the paper, full details about the test procedure, thermal field, load-displacement curves and main remarks about the results are given. In particular, this research work presents the results of five tests for thermal field measurements, that consider four specimens heated in a gas furnace in standard fire conditions (ISO 834) and one specimen heated in an electric furnace in non-standard conditions. Also, the study presents the results of six axial compressive tests. In association to this work, three other papers are presented. In the first companion paper, the results of standard thermal tests are discussed and a numerical-experimental comparison is proposed. In the second companion paper, the results of residual compression tests are discussed and an analytical-experimental comparison is proposed. In the third companion paper, the results of non-standard thermal test and a 'hot' condition compression test are discussed. Also, a numerical-experimental and an analytical-experimental comparisons are proposed for non-standard thermal tests and 'hot' condition compression test respectively.
机译:本文介绍了对全尺寸暴露于火中的钢筋混凝土钢管(RCFST)和钢筋混凝土(RC)短柱(外径457 mm,长度1600 mm)进行的火灾和压缩试验的实验结果。在本文中,给出了有关测试程序,温度场,载荷-位移曲线以及有关结果的主要说明的全部详细信息。尤其是,这项研究工作提出了五项热场测量的结果,这些测试考虑了在标准着火条件下(ISO 834)在煤气炉中加热的四个试样和在非标准条件下在电炉中加热的一个试样。此外,该研究还提出了六个轴向压缩试验的结果。结合这项工作,还提出了另外三篇论文。在第一篇随行论文中,讨论了标准热测试的结果,并提出了数值实验比较。在第二篇配套文件中,讨论了残余压缩测试的结果,并提出了分析实验比较。在第三篇配套文件中,讨论了非标准热测试和“热”条件压缩测试的结果。此外,分别针对非标准热试验和“热”状态压缩试验提出了数值实验和分析实验比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号