首页> 外文会议>Conference on Medical Imaging 2008: Visualization, Image-Guided Procedures, and Modeling; 20080217-19; San Diego,CA(US) >Point-Cloud-to-Point-Cloud Technique on Tool Calibration for Dental Implant Surgical Path Tracking
【24h】

Point-Cloud-to-Point-Cloud Technique on Tool Calibration for Dental Implant Surgical Path Tracking

机译:用于植牙手术路径跟踪的工具校准的点云到点云技术

获取原文
获取原文并翻译 | 示例

摘要

Dental implant is one of the most popular methods of tooth root replacement used in prosthetic dentistry. Computerize navigation system on a pre-surgical plan is offered to minimize potential risk of damage to critical anatomic structures of patients. Dental tool tip calibrating is basically an important procedure of intraoperative surgery to determine the relation between the hand-piece tool tip and hand-piece's markers. With the transferring coordinates from preoperative CT data to reality, this parameter is a part of components in typical registration problem. It is a part of navigation system which will be developed for further integration. A high accuracy is required, and this relation is arranged by point-cloud-to-point-cloud rigid transformations and singular value decomposition (SVD) for minimizing rigid registration errors. In earlier studies, commercial surgical navigation systems from, such as, BrainLAB and Materialize, have flexibility problem on tool tip calibration. Their systems either require a special tool tip calibration device or are unable to change the different tool. The proposed procedure is to use the pointing device or hand-piece to touch on the pivot and the transformation matrix. This matrix is calculated every time when it moves to the new position while the tool tip stays at the same point. The experiment acquired on the information of tracking device, image acquisition and image processing algorithms. The key success is that point-to-point-cloud requires only 3 post images of tool to be able to converge to the minimum errors 0.77%, and the obtained result is correct in using the tool holder to track the path simulation line displayed in graphic animation.
机译:牙种植体是假牙牙科中最受欢迎的牙根置换方法之一。提供术前计划的计算机化导航系统,以最大程度地减少对患者关键解剖结构的损害的潜在风险。牙科工具尖端校准基本上是术中手术中确定手持式工具尖端与手持式标记物之间关系的重要过程。随着术前CT数据到实际坐标的转移,该参数成为典型配准问题的组成部分。它是导航系统的一部分,将进行进一步集成。需要很高的精度,并且通过点云到点云的刚性变换和奇异值分解(SVD)安排此关系,以最大程度地减少刚性配准误差。在较早的研究中,诸如BrainLAB和Materialize之类的商业手术导航系统在刀头校准方面存在灵活性问题。他们的系统需要特殊的刀头校准设备,或者无法更换其他工具。建议的过程是使用定点设备或手持件触摸枢轴和变换矩阵。每当工具尖端停留在同一点时,每次移动到新位置时都会计算该矩阵。实验上获得了有关跟踪装置,图像采集和图像处理算法的信息。关键的成功之处在于,点对点云只需要3个工具的后期图像就能收敛到最小误差0.77%,并且使用工具架跟踪显示在路径仿真线中的结果是正确的图形动画。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号