首页> 外文会议>2014 Intemational Conference of Lighbling Protection >Negative lightning current parameters and detection efficiency for two operational LLS in Catalonia (NE Spain)
【24h】

Negative lightning current parameters and detection efficiency for two operational LLS in Catalonia (NE Spain)

机译:加泰罗尼亚(西班牙东北)两个运行中的最小二乘法的负雷电流参数和检测效率

获取原文
获取原文并翻译 | 示例

摘要

Lightning current parameters derived from Lightning Location Systems (LLS) have been used in the past to assess their influence in the local performance of the Network. The paper presents an analysis of the statistical parameters for negative peak current strokes and flashes in different areas of Catalonia (32 000 km2) for two different LLS operating in this area. “Relative DE” of both LLS in three different regions is found as well. The methodology presented in this paper to determine the “relative DE” is based on the methodology described in a technical document by CIGRÉ. Results show that “relative DE” as well as statistical parameters are linked to Network design respect to the region of interest.
机译:过去已使用从闪电定位系统(LLS)导出的闪电当前参数来评估其对网络本地性能的影响。本文介绍了针对加泰罗尼亚不同地区(32 000 km2)在该地区运行的两个不同的LLS的负峰值电流冲程和闪烁的统计参数的分析。还发现了三个不同区域中两个LLS的“相对DE”。本文介绍的确定“相对DE”的方法是基于CIGRE技术文档中描述的方法。结果表明,“相对DE”和统计参数与网络设计有关的感兴趣区域相关。