The present work uses the results of a CFD model for a wide range of data points to develop a comprehensive correlation for dimensionless airflow rate of solar chimneys. The independent variables in this correlation include height of the chimney (normalized by the chimney depth), absorbing wall temperature and outdoor temperatures (normalized by indoor temperature) and slope of the chimney. This correlation is based on a large number of data produced for chimney angles as low as 30 degrees and as high as vertical chimney, resembling Trombe wall. Details of the CFD model implemented to obtain the data points and curve fitting analysis are presented in this paper. The usefulness of the correlation in evaluating performance of wide range solar chimneys is further discussed.
机译:目前的工作使用CFD模型的结果为广泛的数据点,以发展太阳能烟囱的无量纲的空气流速的全面的相关性。这种相关性中的独立变量包括烟囱的高度(由烟囱深度标准化),吸收壁温度和室外温度(由室内温度标准化)以及烟囱的斜率。这种相关性基于针对烟囱角度(类似于Trombe墙)的低至30度和高至垂直烟囱所产生的大量数据。本文介绍了为获取数据点和曲线拟合分析而实施的CFD模型的详细信息。进一步讨论了相关性在评估大范围太阳能烟囱性能方面的有用性。